TTSD-19172

The default value for Layer order number in the Rebar set properties and in the Rebar leg faceplane that defines where the reinforcing bar legs are created in a rebar set

Tekla Structures creates rebar set leg faces at the reinforced faces of concrete parts or pour objects, or according to the points picked when creating a rebar set.

properties is now Auto. This makes it possible to go back to the default layer order number of zero more easily in the property panecontrol element in Tekla Structures user interface in the form of a side pane window

The property pane can be used to show and modify the properties of model objects.

The property pane can be customized by using the property pane editor.

. Previously you needed to load the standard fileproperty file that Tekla Structures uses by default

Standard file name is standard.* where the symbol * is the file name extension. For example, standard.clm file is used for column properties and standard.clm.more file is used for column user-defined attributes.

.