TTSD-15169

Fixed defect

Last updated June 1, 2018 by Tekla User Assistance tekla.documentation@trimble.com

TTSD-15169

Duplicate bolts on a part (bolt in the same location as another bolt) can now be ignored in part numberingprocess of assigning position numbers to parts, cast units, assemblies, or reinforcement

In Tekla Structures, the position numbers assigned in the numbering are shown in marks and templates, for example.

using the new advanced option XS_BOLT_DUPLICATE_IGNORE.

When set to:

  • FALSE (default): Although the final geometry is the same, the parts may have different numbering results.
  • TRUE: Duplicate bolts are ignored in part numbering.

The tolerated distance for bolts to be considered duplicates can be adjusted with the advanced option XS_BOLT_DUPLICATE_TOLERANCE. Note that the size of the holes are not taken into consideration, only the placement.