Why there is difference in ID to ID dimensions of the tubes between Tekla Structures and HGG post-processing software?

Question: Why there is difference in ID to ID dimensions of the tubes between Tekla Structures and HGG post-processing software? Answer: The length appearing in HGG post processing software is depending upon the 3D geometry and not based on Tekla Solid, so it is accurate. The way Tekla models round solids is by series of segmented facets creating round surface. The differences in dimensions is due to the chord tolerance variable (XS_CHORD_TOLERANCE_FOR_TUBE_SEGMENTS) values which affects the solid creation and thus drawing lengths every time.  If you really want to get close to
Requires Tekla Maintenance
by Trimble Solutions ME
0
  • HGG
  • ID
  • Dimension
  • tube
  • pipe
  • chord
  • tolerance
  • segments

Why do dimension lines in my drawings shift and how do I fix it?

Question: When I open a drawing, the dimension lines in drawings have shifted from their original position. Why is it so and how do I fix it?   Answer: Most likely this is because your model is located far away from the point of origin (0,0,0). We have seen this issue in models which are located several hundreds of kilometers away from the point of origin, e.g. x=400 000 000 mm, y=500 000 000 mm and z=300 000 000 mm. To fix this issue, move the model closer to the point of origin. We always recommend you to place your model as close as possible to the point of origin. See also:
Requires Tekla Maintenance
by Tekla Global Support
4
  • origin
  • point of origin
  • model origin
  • offset
  • dimension offset

Identifying bolts in the model with wrong hole tolerance using organizer

Question:Is it possible to find out bolts in the model having wrong tolerance.? For an Example, My inputs are as below Bolt  Dia.          Bolt Tolerance 12                     2 16                     2 20                     2 24                     2 27                     3 30                     3 33                     3 36                     3 39                     3How to findout bolts in the model if bolt tolerances are not matching as per the above input?Answer: Please follow the step by step procedures 1) Create a filter with the below content for organizer 2) Create a new
Requires Tekla Maintenance
by Trimble Solutions India
4
  • Organizer
  • Bolt
  • Bolt tolerance

Defining file menu switches

This article provides information on how to set the "Switches" using configuration files and Windows registry. For example, user can toggle these switches as preferred from Tekla Structures User Interface File Menu -> Settings -> Switches Model side Drawing side But these settings are also possible to be set or predefined using the following files and Windows registry keys: By default xs_user.default is stored and, when a model is created, loaded from ..\ProgramData\Trimble\Tekla Structures\2019.0\Environments\common\systemAfter the model is saved, these settings are saved in
Requires Tekla Maintenance
by Tekla Global Support
4
  • Menu switches
  • switches
  • windows registry
  • registry

Rotating a revision template vertically

Question: How can we rotate a revision template vertically as shown below?   Answer: See this attached sample portrait template for an example. You can see this template in use in this attached model folder. Refer to drawing C6, which uses the rotated revision template. To place it as per your cell dimension, attach the template to your drawing layout at the desired location. Then insert the actual width required in Template page properties (as shown below) and provide the number of columns using the Min. count and Max. count fields. You may need to play a bit with the values while
Requires Tekla Maintenance
by Trimble Solutions India
0
  • report
  • template

How to Import DWF file in Tekla Structures

Question: We have receievd DWF file from our client. How we can import it or insert it as reference file in Tekla Structures?  Answer: There are online tools available to convert DWF->> DWG (http://www.cadforum.cz/cadforum_en/formats.asp?fmtin=9&fmtout=1). This tool offers a combination of DWF import to Autodesk Navisworks, and using the FBX format to transfer the 3D data from Navisworks to AutoCAD. You can use a similar way to take the CAD model also to other CAD software. Please note that DWF is only a publishing format and the resulting converted CAD model will not have the
Requires Tekla Maintenance
by Trimble Solutions ME
0
  • DWF
  • import
  • insert

Cover-up line is not hiding lines in printout with Tekla Structures 2017 SP3

This is a known issue, and it is already on our development fix list (Reference#124341). The temporary workaround is using the old plot dialog settings.
Requires Tekla Maintenance
by Trimble Solutions India
0
  • cover up line
  • cover up line not showing
  • 2017

How to model Rebar shape with curved and straight legs combined.

We can model Rebar with both curved and straight legs by controlling the curved portion by modifying Bending Radius as required in Reinforcement properties and controlling the straight legs with standard Beding Radius. The same procedure can be followed to model Rebar with multiple legs and mutiple radius of curvature. You can enter a separate value for each bar bend. Separate the values with spaces. We can also use New Rebar Set (From version 2016i onwards) to model these shapes easily.  See Also: Reinforcing bar properties: https://teklastructures.support.tekla.com/2017/en/
Requires Tekla Maintenance
by Trimble Solutions India
0
  • rebar with curved and straight legs
  • curved rebar
  • curved and straight

How to log out from Trimble Identity in Tekla Structures?

Question: When I sign in to Tekla Structures (2017 and onwards) using the Trimble Identity, there is no option to log out. If I click on my user name in Tekla Structures I can only "Open my profile". How to log out?   Answer: The functionality has been changed starting from Tekla Structures 2017. If you see only the option to "Open my profile", that means that you will be automatically logged out when you exit the software. This happens because you did not check the "Stay signed in" checkbox when you signed in with your Trimble Identity account.   If you check the "Stay signed in"
Requires Tekla Maintenance
by Tekla Global Support
0
  • Trimble identity
  • log in
  • sign in
  • Tekla Account

Centralized distribution of Tekla Structures 2017i

Introduction Tekla Structures consists of the following installations: Tekla Structures software installation  Tekla Structures environmentregion- or company-specific settings and information that are predefined in Tekla Structures or that are defined by the userTo be able to use Tekla Structures, the user must install the software and for region-specific settings at least one Tekla Structures environment. The software installation includes the common and blank project environments and the global settings. The common environment and global settings form the basis for all other
Requires Tekla Maintenance
by Software Deployment
5
  • centralized distribution
  • silent install
  • administrative install
  • admin install
  • prerequisites
  • install
  • installer

Failed to write out model changes. Failed to create data.

Q: Our Tekla Model Sharing Write out is failing and we received this error message. What could be the reason? A: There might be several reasons, but this might be caused by long path of the Temp directory (Windows' default location is already quite long). Change the setting XS_SHARING_TEMP to really short (for example, C:\sharing). We have also identified an issue with profile names containing diameter symbols (Ø). If a model contains parts (or cuts) created with such profiles write out cannot be done. At the moment you need to modify your profile catalog and go through the whole model and
Requires Tekla Maintenance
by Area Finland Service
4
  • model sharing
  • failed to create data
  • write out

Tekla Structures User Feedback Program

Do you have great ideas on how Structural BIM software could change the industry? Do you want to test-drive software functionality and solutions inspired by industry leading customer needs, and offer your view on how this may also work within your business?   Shortly about User Feedback Program (UFP) UFP is a program during which the latest implementations and features in the software are presented to testers who have signed up and agreed to the terms and conditions of the Non-Disclosure Agreement (NDA).   Testing is done using Tekla Structures Test Packages and Test Cases. This is a
by Tekla Global Support
4
  • UFP
  • User Feedback Program

Performing a Clean Install of Tekla Structures

Performing a clean install of Tekla Structures In this article we will talk about how to perform a clean install of Tekla Structures. This is something you would do to correct an issue with Tekla running on your compnuter.  Pre-Requisites before Starting 1. Save any customizations or add-on files you might have made to local installations. 2. Back up models to secure location before modifying system files. Removing the old installation On your computer go into the "Control Panel" and open the "Unistall a Program" section. In Uninstall a Program at the top right hand corner search for "Tekla
Requires Tekla Maintenance
by Tekla Support US
4
  • clean install
  • clear registry
  • crash

Error while inserting DWG file as reference

Question: We are not able insert reference CAD file size more than 200MB in to TEKLA model, when we inserted such file it is getting aborted without any error message. Answer: It is happening due to the fact that CAD file is too heavy. So if you are successful in inserting reference file, then do not switch on all layers at once. Try switching on one or few layers at a time from Reference files > Layers. If still fails, then other workaround is, instead of inserting it as one single file, try to segregate it into several CAD files, layer wise and try inserting each file. (Each file
Requires Tekla Maintenance
by Trimble Solutions ME
0
  • CAD
  • DWG
  • reference
  • error

How do I make an Object Browser's Property template work from my Firm or Project folder?

Question: Is there a way to save an Object Browser's Property template from the Organizer so that it can be available from a Firm (or Project) folder? Answer: Yes. First, in your Firm (or Project) folder create the following; Inside the Firm (or Project) folder create a folder named ProjectOrganizerData Inside the ProjectOrganizerData folder create a folder named PropertyTemplates Now, from the Organizer, Export your Property Template to this PropertyTemplates folder. Depending on the version you are using, the exported file will be an xml file or propertytemplate file.  
Requires Tekla Maintenance
by Tekla Support US
5

How to model Rebar for elliptical or oval shaped members.

There are several methods to model reinforcement for unusual geometies like elliptical/ circular members. Generally we can use multiple pick points to model Rebar along the elliptical edge. For verticals, we can use tools like Rebar Polar Array (from Tekla Warehouse) or manual rebar modeling method with Tapered curved bar group settings. Below video contains some example (done in Tekla Structures 2017). Model (Indian Environment) attached for reference. Video: https://teklastructures.support.tekla.com/video-tutorials/en/rebar_elliptical_member
Requires Tekla Maintenance
by Trimble Solutions India
0
  • rebar in curved
  • curved rebar
  • rebar for ellipce
  • elliptical rebar
  • rebar
  • reinforcement

My Flat bars are appearing with metric thickness and metric length. How do I correct this?

I wanted to call out my flat plate profiles as FLAT3/8X3"1/2. When I enter the prefix FLAT as my flat profile prefix all my flat bars in my drawings appear as FLAT9.525X88.9, but the length is correct. How do I correct this?   Answer: Tekla does not recognize the prefix FLAT. You will need to define this prefix in the file called profitab.inp. Here is a link that explains how to add a new profile to the profitab.inp file.
Requires Tekla Maintenance
by Tekla Support US
0

How to use Arabic font on Tekla drawings?

Question: We want to use Arabic font on our drawings. Is that possible in Tekla Structures? Answer: Please follow below steps to achieve English as well as Arabic texts on Tekla drawings. 1) Go to Control Panel >> Region >> Administrative >> Change System Locale >> Select Arabic. 2) Go to Control Panel >> Language >> Add a language >> Arabic (It will add Keyboard layout: Arabic ) 3) Open Tekla Structures drawing and simply insert text. You can switch between English and Arabic by pressing the Alt+Shift key before you start typing. As an 
Requires Tekla Maintenance
by Gaurav Shah
0
  • images
  • Arabic
  • font

What is the effect of changing the cut length in Bolt Properties?

Question: What is the effect of changing the Cut length in Bolt Properties? Answer: The Cut length defines the distance Tekla Structures should search for parts that belong to the bolt group. Parts that are outside the cut length will not be connected by the bolt. If the cut length is A, the search distance is A/2 in both directions from the bolt origin. Example The following example shows the effect of different Cut length settings on a bolt placed between the steel parts shown below. The location of the bolt origin is on the plane between the two parts.    The cut length is centred on
Requires Tekla Maintenance
by Trimble Solutions UK
4.666665
  • Bolt Properties
  • Cut length

Getting started with multiuser

To get started with Multi-User you need to have the Multi-User server, you can install it in any user machine but preferably to be installed on the company server machine.You can find the installation package at Tekla Download: https://download.tekla.com/  After successfully installing the Multi-User server, you should be able to see the server as a service, see below (Control Panel=>Administrative Tools=>Services) Now you will be able to run Tekla Structures in Multi-User modemode in which several users can work on the same model using their own working models. User's workstation side
Requires Tekla Maintenance
by Trimble Solutions ME
0
  • multi - user