Organizer dialog is not visible

If an Organizer dialog, like Categories or Object Browser is not visible, you can reset the dialog positioning by deleting the AvalonDockConfig.xml file, then reopening Organizer.   C:\Users\<user>\AppData\Local\ProjectOrganizer\AvalonDockConfig.xml This might happen after using several screens and then changing to one screen.
Requires Tekla Maintenance
by Tekla Global Support
0
  • Organizer
  • categories
  • Object Browser
  • dialog
  • window
  • missing
  • disappear

Is it possible to see which kind of licenses are used by different users?

Question: Is it possible to see which kind of licenses are currently used by different users? Answer: Yes, there is a way to do that. But you have to use command lines. Open the cmd and then go to the license server installation folder and follow the instructions below. The syntax is: lmutil.exe lmstat -a -c <port>@<server name> For example: lmutil.exe lmstat -a -c 27001@licenseserver The command will output a list of different license types, the number of licenses issued and the license expiration dates on the server. It will also list the usernames using a certain type of
Requires Tekla Maintenance
by Area Finland Service
0

Unable to connect to Tekla Structures license server when using Microsoft DirectAccess

Question: I can’t connect to our license server when I’m using Microsoft DirectAccess. First, there seems to be no problem in the connection to the server machine. Second, I have this problem only when I’m using DirectAccess. What is the reason to this problem and what can I do to fix it?Answer: The connection is probably using IPv4, when it needs to be using IPv6. You can configure the licensing system to use IPv6 for hostname resolution by setting the environmental variable FNP_IP_PRIORITY=6 in Windows.To do this: 1. Search for “environment variable” and select Edit the system environment
Requires Tekla Maintenance
by Area Finland Service
0
  • cannot connect to license server. connectivity problem
  • VPN
  • Connect to the license server

Another user having pair at Company X is reserving the email address used by the current user at Company Y

Question: We have one user who wants to use model sharing but when he wants to join the model he had nothing in the list of shared models. He was invited to join the model and has model sharing license. We found the following error message in the log files: Another user having (AtcUserId - CompanyId) pair (xxx) at "Company X" is reserving the email address james.smith@test.xyz used by the current user (xxx) at "Company Y" What is the problem and how to solve it? Answer: This means that james.smith@test.xyz has been moved from organization "Company X" to organization "Company Y" in
Requires Tekla Maintenance
by Tekla Global Support
0

Model sharing and firm folder

Question: How to set up a firm folder in a company that has offices in different locations? Each location has its own firm folder on its own server and the locations work in the same Tekla Model Sharing model. What to do when there are changes in firm files? Answer: You can only give one location for the XS_FIRM advanced option, so multiple path definitions are not possible. However, the XS_FIRM advanced option is of MODEL(SYSTEM) type, which is not moved to other users when writing out/reading in. This means that you can use your local path, and these can be different between offices. So,
Requires Tekla Maintenance
by Tekla Global Support
0

BIM Questions in PAS 91:2013+A1:2017

Guidance for Tekla customers completing the BIM Questions in PAS 91:2013+A1:2017 BSI PAS 91 is a publicly available specification (PAS) that sets out the content, format and use of questions that are widely applicable to prequalification for construction tendering. To be eligible for prequalification, it is necessary that suppliers are able to demonstrate that they possess or have access to the governance, qualifications and references, expertise, competence, health and safety/environmental/financial and other essential capabilities to the extent necessary for them to be considered
Requires Tekla Maintenance
by Trimble Solutions UK
0
  • BIM
  • Building Information Modelling
  • PAS 91:2013+A1:2017

Tekla Structures and COBie

Guidance for Tekla customers on COBie and the relationship between Tekla Structures and COBie Sub-contractors are increasingly asked as part of their tender submissions how the information they provide fits into a BIMprocess of modeling and communicating the structure of a building in detail to benefit the entire construction life cycleBIM facilitates the exchange and use of building information in a digital format. workflow. A typical question that a Tekla customer may have to answer is “Does the business have a documented process for producing COBie containers?” In this article we are
Requires Tekla Maintenance
by Trimble Solutions UK
0
  • BIM
  • Building Information Modelling
  • COBie

Tekla Structures 2019 Hardware Recommendations

Recommendations for Tekla Structures workstations Tekla Structures hardware recommendations are based on the set-ups that have been used in testing Tekla Structures and proven to be compatible with Tekla Structures. In addition to the set-ups presented in this document, there are many other suitable set-ups available. You can use this document as a guideline in choosing new hardware, but bear in mind that the equipment and labels presented in this document are not the only suitable hardware set-up. The main criterion when choosing hardware is reliable performance. If you are considering a
by Tekla Global Support
5
  • Tekla Structures 2019 Hardware Recommendations
  • hardware recommendations

Wrap text (Multiple line text) in template editor

Question: Is it possible to use the Wrap text (Multiple line text) in Value field in template editor? Answer: Yes, It is possible from Template editor version 3.5 (TS2017i), You can now enter multiple lines of values in the Name field in the Value Field Properties dialog box. You also need to enter the number of lines. The lines will be reserved even if you do not enter multiple lines. For an example, You can refer https://teklastructures.support.tekla.com/2017i/en/admin_rel_2017i_template_editor to know more about the same.
Requires Tekla Maintenance
by Trimble Solutions India
0
  • template
  • wrap text
  • multiple text

TEXT MASK (FRAME) in view label in exported drawings

Question: How to avoid TEXT MASK (FRAME) in view label if I am using the new drawing export option (Export drawings to DWG/DXF)? See below Snap which is having frame around "3d" in exported drawing but no frame around the same view lable "3d"in Tekla drawings. Answer: It can be controlled by changing the Mask/Frame option settings in your reference drawings(DWG) which you are using during the drawing export. You need to follow the below procedure to change the Mask/Frame settings once you open the reference drawing. 1) Go to “Annotate” Menu > “Mask” , then click or Type “Mask” in your
Requires Tekla Maintenance
by Trimble Solutions India
0
  • frame
  • MASK
  • BORDER
  • view label
  • TEXT AROUND
  • new drawing export
  • Export drawings to DWG/DXF
  • Export drawing
  • Export drawings
  • Export DWG

Hardware recommendations for running Tekla Structures on Citrix

Using Tekla Structures with the Citrix application and desktop virtualization is a flexible and safe way to quickly add users to Tekla Structures projects without locally installing Tekla Structures and copying project data to a user's computer. Supported platforms: Citrix XenApp 7.6. Citrix XenDesktop 7.6 or VMware vSphere 6.0 hypervisor. Recommended server specifications: Fast graphics card, NVIDIA GRID K520 or the newer NVIDIA Tesla GPUs 8 GB to16 GB of main memory for each user, depending on the usage. High-end CPUs, such as the latest generation of Intel Xeon E5 or E7 families. Windows
by Tekla User Assistance
0
  • Citrix

Join_sharing_in_progress

Question: I cannot join to a model sharing model. Only xxx.Join_sharing_in_progress file is stored in the local model folder. When opening that file, there is text “If this file exists, model is corrupt.” What causes the problem? Answer: That xxx.Join_sharing_in_progress is created as a first file in the local folder during joining to a shared model. If it remains there, something has gone wrong during joining, so then the local model is handled as corrupted. We have had cases where for example anti-virus software or some other software interferes the file copying and causes this file to be
Requires Tekla Maintenance
by Tekla Global Support
0

How to disable my Support Tool from opening automatically?

Question: My support tool opened in several windows while I was working in Tekla Structures. Why did this happen and can I prevent Support Tool from opening automatically? Answer: Since 2016i there has been a feature that automatically opens the Contact support tool when unhandled exceptions occur. This allows you to send the error messages and the model you are working on to your local support office for investigation of the problem. We have been reported about issues where multiple Support Tool windows open at the same time making it impossible to send any error messages to support or to
Requires Tekla Maintenance
by Area Finland Service
5
  • Support tool

Random crash or freeze of Tekla Structures

We have received several reports of random crashes or freezeto prevent Tekla Structures from updating annotation objects and certain drawing view properties in a drawing when it updates the drawing as the model changesWhen a drawing is frozen, only part geometry is updated when the model changes.-states of Tekla Structures, especially related to versions 2018 and 2018i. Those seem to occur very randomly, although such problems were identified more often after the latest Microsoft Windows update (version 1803) has been installed. When Tekla Structures freezes, the applicationpart of Tekla
Requires Tekla Maintenance
by Tekla Global Support

How can I define my own hatch patterns?

Question: I would like to add my own hatch pattern to the available hatch patterns for drawing fills. How can I do this? Answer: You will need to edit the hatch_types1.pat file. The default location for this file is ...\TeklaStructures\<version>\Environments\common\inp. For some environments it is also located in ...\TeklaStructures\<version>\Environments\<environment>\inp. In these cases XS_INP  has been used to define the folder from which this file is read. For example, in the US Imperial environment the following line exists in env_US_imperial.ini: set XS_INP=%XSDATADIR
Requires Tekla Maintenance
by Tekla Global Support
0
  • hatch
  • pattern
  • hatching
  • fill

Why did my Support tool open automatically?

Question: Why did my Support tool open automatically while I was working in Tekla Structures?Answer: Since 2016i there has been a featurepart of Tekla Structures functionality that is maintained and owned by Trimble Solutions and that is included in the Tekla Structures installation that automatically opens the Contact support tool when unhandled exceptions occur. This allows you to send the error messages and the model you are working on to your local support office for investigation of the problem.
Requires Tekla Maintenance
by Tekla Global Support
0

Sketch editor profiles in firm folder & profile catalog

Question: How to add a sketch editor profile to your firm folder & profile catalog? Answer: When you created a Sketch editor profile, the profile is not located in the profile catalog of the model but in the xslib.db1 file of the model. To export the profile go to profile catalog in Menu >> Catalogs >> Profile catalog and export the profile. The profile will be exported as an .uel file. If you want to use this profile in the firm or project folders, copy the .uel file in any location in the firm folder or project folder (e.g. C:\Firm\User_profiles_uel). Set the advanced
Requires Tekla Maintenance
by Tekla Global Support
0
  • Sketch profiles firm project uel profile catalog

How to fix the positioning of your parametric .clb-profiles

Question: My profile's positioning does not work correctly. What to do? Answer: When creating profiles in .clb format there are 2 main issues that affect the positioning: The profile has to be divined centered to its neutral axis, to ensure the profile rotates around its reference line. To enable On plane & At depth positioning of the profile you have to include "b" & "h" parameters.  Example 1: When I set On plane to down the profile and its reference line are not touching, even when Plane offset = 0.00 mm. Solution: In the picture above you see the profile CORBEL_A. When you open
Requires Tekla Maintenance
by Tekla Global Support
5
  • clb positioning profile incorrect

Deleting history in model sharing project

Question: I have a model sharing project with many users and history.db file is really large, it is over 1 GB. Do you have some good guidelines how the history could be deleted in a big project? Answer: Large history data can really affect the model performance also in model sharing models. So it is good to consider whether it is really needed and delete if not. But deleting the history is not straight forward process and requires some planning. It is not enough that just one user changes the advanced option XS_CLEAR_MODEL_HISTORY to TRUE. Changing this options requires restarting Tekla
Requires Tekla Maintenance
by Tekla Global Support
4

Component not created

Question: What could be the reason when some components are coming in red cone & the DOS window is not getting created? So for example steel1.exe process is not running when looking in Windows Task Manager. Answer: There might problem that if the model is locating in very long path, the component is not created. Model name and path got some limitations since Tekla Structures 2016 version, but it is still possible to copy model to another location with very long path. Try moving the model to a shorter path. Model name maximum length is 40 characters and 140 characters for path.  
Requires Tekla Maintenance
by Tekla Global Support
0

Pages