Duggans Eaves Beam to Stanchion - Parts tab

Tekla Structures
Not version-specific
Tekla Structures
Cold Rolled
Duggan Steel
duggans
eaves beam to stanchion
parts tab
Environment
Not environment-specific

Use the Parts tab in the Duggan Steel Eaves Beam to Stanchion Properties panel to control the member properties of the items created by the joint.

Image
tekla-structures-duggans-eaves-to-stanchion-parts-tab.png


OptionDescriptionDefaultOther
Connecting ProfileThis specifies a profile to be used for the centre portion of the fixing bracket. The profile will be positioned according to its type, ie. a channel or angle will be placed with its back aligned to the centre of the plates where as a rectangular hollow section would be placed centrally. The default profile will be determined appropriately from the eaves beam size. 
Eaves PlateThis specifies the profile to be used for the plate bolted to the column if the bolted option is selected on the parameters tab.The default setting is DP-EAVES-STRUT-COLUMN-PLATE 
Pos_No
(Part position number)
The part position number consists of a prefix and a start number.
1. Prefix
2. Start number
Some connections have a second row for the part position number where you can enter the assembly position number.
The part position number defined in the connection dialog box overrides the settings defined in the components settings in File menu --> Settings --> Options. In addition to that it will use the values taken from the data files.
Image
tekla-structures-parts-tab-pos-no.png
MaterialThis is the material grade that will be used for the fitting bracket created in the joint.The default setting is Steel_Undefined 
NameThe profile name cannot be amended.  

See also

Duggans cold rolled - Important information
Duggans Eaves Beam to Stanchion
Duggans Eaves Beam to Stanchion - Parameters tab
Duggans Eaves Beam to Stanchion - Plate Dimensions tab
Duggans Eaves Beam to Stanchion - Bolts tab