Extensions

Kingspan Horizontal Cladding Sleeve (120)

The Kingspan Horizontal Cladding Sleeve connection is used to create a cleat connection between one or two Multichannel rails to a column/stanchion. It can be used for sleeved joints, butt joints, in the middle of double span purlins/rails and at gable ends. It should not be used for connections to hip rafters for which a separate joint is available. For simplicity, this help text, and the joint dialogue, will refer only to purlins and rafters, but unless explicitly stated otherwise, these terms should be taken to mean purlins/rails and rafters/stanchions.
by Trimble Solutions UK
0

Kingspan Horizontal Cladding Support Column (33)

The Kingspan Horizontal Cladding Support Column macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog.
by Trimble Solutions UK
0

Kingspan Multichannel Base Cleat (4)

The Kingspan Multichannel Base Cleat is provided as a detail for the bottom of Multichannel columns. It will define either an autoformed end for the column, single/double cold rolled cleats, or single/double hot rolled cleats. 
by Trimble Solutions UK
0

Kingspan Non-Continuous Rail (106)

The Kingspan Non-Continuous Rail system joint is normally used when the specified column face to cladding distance is less than that possible for the standard purlin/rail joint. The joint can handle flush or recessed sheeting lines. A non-standard cleat, (either angle or tee), is bolted to the column, and bolted to the rail along the standard gauge lines.
by Trimble Solutions UK
0

Kingspan Non-Standard Horizontal Cladding Support (34)

The Kingspan Non-Standard Horizontal Cladding Support macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog.
by Trimble Solutions UK
0

Kingspan Non-Standard Tie (6)

The Kingspan Non-Standard Tie macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog.
by Trimble Solutions UK
0

Kingspan Panel Joint at Column (11)

The Kingspan Panel Joint at Column macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog. They are recorded or created manually and stored as .cs file in a folder defined with the advanced option XS_MACRO_DIRECTORY.Macros can, for example, be used for creating drawings or reports.Macros are sometimes used to run an application. can be used to connect vertical G140/150 sections back to the column face.
by Trimble Solutions UK
0

Kingspan Panel Joint at Mid-Span (21)

The Kingspan Panel Joint at Mid-Span connects between a horizontal Multibeam and one or two vertical Multichannels. 
by Trimble Solutions UK
0

Kingspan Shear Plate to Hip (8)

The Kingspan Shear Plate(1) part that represents a flat structure(1) In some contexts, for example in analysis, the term plate object may be used to refer to plates.(2) plate that represents a steel structure(2) Plate is mainly used as a connection piece or as a floor plate. to Hip connection is used to create the appropriate items to connect one or two purlins to a hip rafter.
by Trimble Solutions UK
0

Kingspan Simple Hip (14)

The Kingspan Simple Hip connection is provided to form a connection between a single cold rolled purlin and a hip or valley rafter. 
by Trimble Solutions UK
0

Kingspan Standard Horizontal Cladding Support (31)

The Kingspan Standard Horizontal Cladding Support macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog.
by Trimble Solutions UK
0

Kingspan Standard Tie Bay (10)

The Kingspan Standard Tie Bay macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog.
by Trimble Solutions UK
0

Kingspan Apex Tie Bay (12)

The Kingspan Apex Tie Bay macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog. They are recorded or created manually and stored as .cs file in a folder defined with the advanced option XS_MACRO_DIRECTORY.Macros can, for example, be used for creating drawings or reports.Macros are sometimes used to run an application. can be used to define multiple ties within a bay, between the two Multibeams at an apex.
by Trimble Solutions UK
0

Kingspan Apex Ties (9)

The Kingspan Apex Ties macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog. They are recorded or created manually and stored as .cs file in a folder defined with the advanced option XS_MACRO_DIRECTORY.Macros can, for example, be used for creating drawings or reports.Macros are sometimes used to run an application. can be used to define various types of ties between the two Multibeams at an apex. 
by Trimble Solutions UK
0

Kingspan Autoform Detail (3)

The Kingspan Autoform Detail joint only works with Kingspan Multichannel sections and is used to create an autoform at the end of a Multichannel. 
by Trimble Solutions UK
0

Kingspan Autoform One Sided (20)

The Kingspan Autoform One Sided connection is used to connect a Multichannel (compound or single) to a main member. 
by Trimble Solutions UK
0

Kingspan Autoform Two Sided (22)

The Kingspan Autoform Two Sided connection is used to connect two Multichannels (compound or single) to a main member. 
by Trimble Solutions UK
0

Kingspan Cleader Angle (13)

The Kingspan Cleader Angle connection is used to create a bolted connection between a manually modelled cleader angle and the top or outer flange of a Multibeam/Multichannel section. 
by Trimble Solutions UK
0

Kingspan cold rolled - Important information

When utilising the Kingspan cold rolled system it is important to take the following information into account.
by Trimble Solutions UK
0

Kingspan Cold Rolled Sleeved (28)

The Kingspan Cold Rolled Sleeved connection is used to connect one or two purlins/rails to a rafter/stanchion. It can be used for sleeved joints, butt joints, in the middle of double span purlins/rails, and at gable ends. It should not be used for connections to hip rafters for which a separate joint is available. For simplicity, this help text, and the joint dialogue, will refer only to purlins and rafters, but unless explicitly stated otherwise, these terms should be taken to mean purlins/rails and rafters/stanchions.
by Trimble Solutions UK
0

Pages

.