Hello!

Did you know that logged in users can see a lot more content?

Extensions

Kingspan Non-Continuous Rail (106) - Parameters tab

Use the Parameters tab in the Kingspan Non-Continuous Rail Properties panel to control how the connecting members are defined within Tekla Structures.
by Trimble Solutions UK
0

Kingspan Non-Continuous Rail (106) - Bolts tab

Use the Bolts tab in the Kingspan Non-Continuous Rail Properties panel to override the default bolt data. 
by Trimble Solutions UK
0

Kingspan Non-Continuous Rail (106)

The Kingspan Non-Continuous Rail system joint is normally used when the specified column face to cladding distance is less than that possible for the standard purlin/rail joint. The joint can handle flush or recessed sheeting lines. A non-standard cleat, (either angle or tee), is bolted to the column, and bolted to the rail along the standard gauge lines.
by Trimble Solutions UK
0

Kingspan Multichannel Base Cleat (4) - Parameters tab

Use the Parameters tab in the Kingspan Multichannel Base Cleat Properties panel to control how the autoform/cleats are defined within Tekla Structures.
by Trimble Solutions UK
0

Kingspan Multichannel Base Cleat (4)

The Kingspan Multichannel Base Cleat is provided as a detail for the bottom of Multichannel columns. It will define either an autoformed end for the column, single/double cold rolled cleats, or single/double hot rolled cleats. 
by Trimble Solutions UK
0

Kingspan Shear Plate to Hip (8) - Parameters tab

Use the Parameters tab in the Kingspan Shear Plate(1) part that represents a flat structure(1) In some contexts, for example in analysis, the term plate object may be used to refer to plates.(2) plate that represents a steel structure(2) Plate is mainly used as a connection piece or as a floor plate. to Hip Properties panel to control how the connecting members are defined within Tekla Structures.
by Trimble Solutions UK
0

Kingspan Shear Plate to Hip (8) - Bolts tab

Use the Bolts tab in the Kingspan Shear Plate(1) part that represents a flat structure(1) In some contexts, for example in analysis, the term plate object may be used to refer to plates.(2) plate that represents a steel structure(2) Plate is mainly used as a connection piece or as a floor plate. to Hip Properties panel to override the default bolt data.
by Trimble Solutions UK
0

Kingspan Shear Plate to Hip (8)

The Kingspan Shear Plate(1) part that represents a flat structure(1) In some contexts, for example in analysis, the term plate object may be used to refer to plates.(2) plate that represents a steel structure(2) Plate is mainly used as a connection piece or as a floor plate. to Hip connection is used to create the appropriate items to connect one or two purlins to a hip rafter.
by Trimble Solutions UK
0

Kingspan Panel Joint at Mid-Span (21) - Parameters tab

Use the Parameters tab in the Kingspan Panel Joint at Mid-Span Properties panel to control how the connecting members are defined within Tekla Structures.
by Trimble Solutions UK
0

Kingspan Panel Joint at Mid-Span (21)

The Kingspan Panel Joint at Mid-Span connects between a horizontal Multibeam and one or two vertical Multichannels.
by Trimble Solutions UK
0

Kingspan Panel Joint at Column (11) - Parts tab

Use the Parts tab in the Kingspan Panel Joint at Column Properties panel to control the member properties of the items created by the macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog.
by Trimble Solutions UK
0

Kingspan Panel Joint at Column (11) - Parameters tab

Use the Parameters tab in the Kingspan Panel Joint at Column Properties panel to control how the connecting members are defined within Tekla Structures.
by Trimble Solutions UK
0

Kingspan Panel Joint at Column (11)

The Kingspan Panel Joint at Column macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog. They are recorded or created manually and stored as .cs file in a folder defined with the advanced option XS_MACRO_DIRECTORY.Macros can, for example, be used for creating drawings or reports.Macros are sometimes used to run an application. can be used to connect vertical G140/150 sections back to the column face.
by Trimble Solutions UK
0

Kingspan Non-Standard Tie (6) - Parameters tab

Use the Parameters tab in the Kingspan Non-Standard Tie Properties panel to control how the connecting members are defined within Tekla Structures.
by Trimble Solutions UK
0

Kingspan Standard Tie Bay (10) - TieWires tab

Use the TieWires tab in the Kingspan Standard Tie Bay Properties panel to control the diagonal ties created by the macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog. They are recorded or created manually and stored as .cs file in a folder defined with the advanced option XS_MACRO_DIRECTORY.Macros can, for example, be used for creating drawings or reports.Macros are sometimes used to run an application..
by Trimble Solutions UK
0

Kingspan Standard Tie Bay (10) - Parameters tab

Use the Parameters tab in the Kingspan Standard Tie Bay Properties panel to control how the connecting members are defined within Tekla Structures.
by Trimble Solutions UK
0

Kingspan Standard Tie Bay (10)

The Kingspan Standard Tie Bay macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog.
by Trimble Solutions UK
0

Kingspan Shear Plate to Hip (8) - Parts tab

Use the Parts tab in the Kingspan Shear Plate(1) part that represents a flat structure(1) In some contexts, for example in analysis, the term plate object may be used to refer to plates.(2) plate that represents a steel structure(2) Plate is mainly used as a connection piece or as a floor plate. to Hip Properties panel to control the member properties of the items created by the joint.
by Trimble Solutions UK
0

Kingspan Apex Ties (9) - Parts tab

Use the Parts tab in the Kingspan Apex Ties Properties panel to control the member properties of the items created by the macrosaved series of actions that includes instructions for a programMacros are located in the applications and components catalog.
by Trimble Solutions UK
0

Kingspan Apex Ties (9) - Parameters tab

Use the Parameters tab in the Kingspan Apex Ties Properties panel to control how the connecting members are defined within Tekla Structures.
by Trimble Solutions UK
0

Pages

.