Piece Mark Shows 1 instead of the Part Mark on the DSTV file

Tekla Structures
Not version-specific
Tekla Structures
CNC
DSTV
NC
dstv error
piece mark shows 1
part mark shows 1
phase instead of part mark
nc file shows wrong piece mark
Peddinghaus
Raptor
Environment
United States (Imperial)
United States (Metric)

When I import a DSTV File into the Shop interface the Part Position and the Phase appear in the incorrect fields. How do I modify the DSTV file to correct this?

The DSTV file has lines at the top of the file that contains all the information about the part. The order of the lines of information is set to be in a specific order according to the DSTV Standard Format. The order the shop machine software reads these lines might be different than the default.

Tip:
When possible, it is recommended to change machine software settings. Changing the machine software settings reduces the possibility of separate NC files (and settings) for each machine.

Steps to Rearrange Header Lines

1.  On the File menu, click Export> NC Files. 
2. Click the Header Button.

Image
Screenshot showing the NC File dialog with an arrow pointing to the Header… button.

3. The NC File Header Information dialog will appear showing all the Elements being exported to the Header. Select the element for Piece identification.
4. Click the Move up button. This will move the Piece identification above the Phase identification basically swapping the two Elements.

Image
NC File Header Information dialog with Piece identification highlighted and an arrow pointing to the Move up button.
Image
icon_tip.png
You can continue swapping the elements around to get the order you need for the shop machine interface if needed. If you get the elements too for out of order you can click the Default button to reset back to the original order.

5. Click OK when finished to close the dialog box.
6. Create NC files as normal.

 

 

 

 

 

 

 

 

 

 

Was this helpful?