XS_AD_ELEMENT_ANGLE_CHECK_ANGLE_DIFF_LIMIT

Tekla Structures
2021
Tekla Structures

XS_​AD_​ELEMENT_​ANGLE_​CHECK_​ANGLE_​DIFF_​LIMIT

Category

Analysis & Design

Use to set a limit angle between physical part and analysis model member, in order to test the validity of the analysis model. When the angle is greater than the limit, a message appears and a warning is added to the log. Small differences in angles are usual in the analysis model of a truss, for example. The default value is 10.0.

This advanced option is model specific and the setting is saved in the options database.