Use to specify to which value (Yes or No) the Moment connection symbols option is set when the Get results command is used in the analysis model. The Moment connection symbols option is available on the End conditions tab in the user-defined attributes properties dialog box of the part, and it defines whether the moment connection symbols are shown in drawings.

Set the advanced option to one of the following values:

  • yz: if the rotations ry and rz are fixed in the analysis model, the value Yes is used, otherwise No is used.

  • xyz: if all rotations are fixed in the analysis model, the value Yes is used, otherwise No is used.

  • z: if the rotation rz is fixed in the analysis model, the value Yes is used, otherwise No is used.

  • The advanced option is not set: The value you have set manually in the Moment connection symbols option is used.

The default is yz.

This advanced option is model specific and the setting is saved in the options database.