Defect number | Development area | Description |
---|---|---|
TSAC-4641 | Concrete components | Embedded anchor (008): The creation of thickening was not working if the cast unit has some parts under isolation. This has now been fixed. |
TSAC-4650 | Concrete components | Reinforced concrete stair (95) : The creation of the last L rebar now works when the No option is used. |
TSAC-4679 | Concrete components | Wall layout T connector: Previously, opening the Wall layout T connector properties from the model could cause Tekla Structures to crash. Now this does not happen anymore. |
TSAC-4851 | Concrete components | Corbel connection (14): Fixed crashes when custom components on the column is created. |
TSAC-4883 | Concrete components | Mesh bars: The Ignore openings smaller than option on the Detailing tab now works correctly again. |
TSAC-4906 | Concrete components | Corbel connection (14): Previously, in some situations, a custom part on the column was created in an unexpected position. This has now been fixed. |
TSAC-4985 | Concrete components | Sandwich and double wall: Classes are now correctly set to the main insulation when the insulation is split in one direction. Previously, when you split the insulation in only the horizontal or vertical direction, the middle panels would get properties as if the edge strips were split. This has now been fixed. |
TSAC-5033 | Concrete components | Mesh bars, Mesh bars by area: If the top or bottom cover thickness is negative or bigger than the thickness of the input part, the component now creates rebar groups outside of the concreate part instead of failing. |
TSAC-2020 | Steel components | HSS Brace special (66): Previously, the gusset plate was created with an incorrect shape when the default size values were used. This has now been fixed. |
TSAC-4020 | Steel components | Column with stiffeners W (182), Column with stiffeners (186), Column with stiffeners S (187), Column with stiffeners (188): Previously, with some sloped conditions, the bolt edge distance was not correct. This has now been fixed. |
TSAC-4360 | Steel components | U.S. Base plate (1047): Previously, the position of holes in the cast plate was incorrect. This has now been fixed. |
TSAC-4563 | Steel components | Bent plate (190): Previously, bent plates were not positioned correctly according to the option selected in the component dialog box. This has now been fixed. |
TSAC-4590 | Steel components | Cold rolled sleeved (2): Previously, when it was specified that a sleeve profile should be created as a C profile, the sleeve profile was created incorrectly. This has now been fixed. |
TSAC-4770 | Steel components | Seating (39): Previously, when the primary part and secondary parts were rotated too much, the connection was broken. This has now been fixed. |
TSAC-4791 | Steel components | Splice plate 2 (62): Previously, double plates were not bolted. This has now been fixed. |
TSAC-4828 | Steel components | Eaves haunch (102): It is now possible to specify part names. |
TSAC-4842 | Steel components | JP Full depth special (185): Previously, the position of the opposite web stiffener was not correct. This has now been fixed. |
TSAC-4843 | Steel components | JP Full depth special (185): Previously, the tab plate was created with incorrect dimensions. This has now been fixed. |
TSAC-4927 | Steel components | Z pan (S74): Previously, when the length of the front part of the step was specified as zero, the top step was created incorrectly. This has now been fixed. |
TSAC-5121 | Steel components | Eaves haunch (102): Compensation stiffeners now get the correct part prefix and start number. |
TTSD-37961 | Steel components | Previously, in some situations, similar parts with regular bolt holes and with slotted holes received the same number in numbering. This has now been fixed. |
TTSD-39164 | Steel components | Mirroring single leg rebar groups with different From plane values at the start and end now works for all spacing types. |
TTSD-41269 | Organizer | Previously, the project properties were not always exported to the Excel. This has now been fixed. |
TTSD-34275 | Import, export, interoperability | Reference models: IFC reference models from Revit did not sometimes include some slabs. This has now been fixed. |
TTSD-34846 | Import, export, interoperability | Reference models: Sometimes inserting a reference model failed because of special characters. All characters below 256 are allowed in a reference model file name: both ASCII (0-127) and extended ASCII (128-255). If the file name contains unsupported characters, you will get a warning message. |
TTSD-39788 | Import, export, interoperability | Reference models: Cyrillic characters are now supported in the path and file name. |
TTSD-39966 | Import, export, interoperability | Security of the Tekla Warehouse connection has been improved. |
TTSD-40002 | Import, export, interoperability | IFC export: The attribute WEIGHT_ONLY_REBARS now gives a correct value for a pour unit instead of 0.0 when exported as a part of an IFC property set. |
TTSD-40123 | Import, export, interoperability | IFC4 export: Exported pour B-reps were sometimes not solid, and the volume calculation from the object failed. This has now been fixed. |
TTSD-40127 | Import, export, interoperability | Reference models: Reference model conflicts may cause a situation where the reference model appears with a warning symbol. This has now been fixed. |
TTSD-40453 | Import, export, interoperability | IFC2x3 export: The IFC2x3 export did not always export surface treatment. This has now been fixed. |
TTSD-40509 | Import, export, interoperability | IFC2x3 export: The export now works also when you have defined a base point that has a negative north direction angle value. |
TTSD-40848 | Import, export, interoperability | Reference models: The local placement was written incorrectly in mh software, which is why the IfcElementProxy objects were scaled incorrectly in Tekla Structures. This has now been fixed. |
TTSD-40888 | Import, export, interoperability | Reference models: In DWG reference models, some short lines were sometimes not shown if there were also relatively long lines in the DWG file. This has now been fixed. |
TTSD-41410 | Import, export, interoperability | Export drawings to DWG/DXF: The export no longer crashes if the font is not set for some text elements in the drawing. In this case, Arial will be used by default. |
TTSD-41419 | Import, export, interoperability | Previously, when you imported a user-defined attribute (UDA) that had the special_flag option set to yes , the objects with the UDA were not marked as modified in some cases. This has now been fixed. |
TTSD-41443 | Import, export, interoperability | IFC2x3 export: The export was not always correct if a part was extended with a fitting. This has now been fixed. |
TTSD-42070 | Import, export, interoperability | Reference models: A Tekla Structures application error occurred when you opened an older version model and then changed to another model without saving the currently open model first. This has now been fixed. |
TPLED-189 | Templates and reports | Template Editor: Template Editor no longer crashes when valuefields with very long rules are copied using the clipboard. |
TPLED-191 | Templates and reports | Template Editor: The grid can again be selected by 1/128 inch steps in environments using imperial units. |
TTSD-40216 | Templates and reports | Summing duplicate valuefield values in the row combine did not work when the valuefield had a CopyField function in the formula. This has now been fixed. |
TTSD-41615 | Templates and reports | Properties that use a "." format, such as ASSEMBLY.POUR_UNIT , can now be used to define property sets that report pour unit and pour object properties. |
TSAC-4387 | Drawings | Dimensioning to the nearest edge (Measure from set to Nearest edge) now works correctly also if the main part is filtered away from the view. Previously, the dimension was created to the main part even if the part was invisible. |
TSAC-4388 | Drawings | Shape dimensions now work also when the Measure from setting is set to Part or Filter. Previously, the main part was always included in the dimension line. |
TTSD-23117 | Drawings | The drawing snapshot overlay caused problems when you tried to save the model. Now the snapshot overlay is closed when you save the model. |
TTSD-35243 | Drawings | The drawing layout was sometimes missing from drawing snapshots. This has now been fixed. |
TTSD-35263 | Drawings | The cloning of the merged weld marks has been improved. |
TTSD-38402 | Drawings | Previously the Exclude parts according to filter option changed to None if the Top in form face location was changed. This has now been fixed. |
TTSD-38567 | Drawings | The default hatch scale when placing a hatch outside a view is now the same as it was in Tekla Structures version 2018. |
TTSD-38664 | Drawings | When the location of one rebar was adjusted manually, some rebar marks, also from other rebars, were moving. This has now been fixed. |
TTSD-39483 | Drawings | Document manager: Document manager now ensures a default and stable sort order when identical values are encountered. Previously, several rows could have the same sort property values so their position in the document list could be different, depending on the document events and the order the documents were found. |
TTSD-39496 | Drawings | Drawing view properties (.vi ) files were not read from XS_PROJECT/XS_FIRM subfolders. This has now been fixed. |
TTSD-39632 | Drawings | The pull-out pictures now appear in rebar dimension marks on rebar sets. |
TTSD-39951 | Drawings | Moving weld marks from one view to another could break the leader line handles. This has now been fixed. |
TTSD-39974 | Drawings | Printing to PDF could fail when the drawing contained symbols that had no width or height defined. This has now been fixed. |
TTSD-40077 | Drawings | You can now change the units for the cc target element in a drawing mark (UK environment/Cast-in-situ role). |
TTSD-40629 | Drawings | Dragging dimensions in a drawing could cause an application error in some rare cases. This has now been fixed, and the application error no longer occurs. |
TTSD-40674 | Drawings | The ASSEMBLY_POS attribute did not report any value when it was used in bolt marks in drawings. This has now been fixed. |
TTSD-40703 | Drawings | The TOP_LEVEL and BOTTOM_LEVEL attributes now give correct values for dimension tags based on the Location by setting of the drawing view. |
TTSD-40839 | Drawings | Rebar placing in drawings could sometimes cause crashing. This has now been fixed. |
TTSD-40977 | Drawings | Tekla Structures no longer crashes when you open a specific drawing. |
TTSD-41267 | Drawings | Reference models in drawings: The outline representation now follows the settings of visible layers on the model side. Previously all layers were shown. |
TTSD-41398 | Drawings | The stability of cloning has been improved. |
TTSD-41431 | Drawings | Polylines in drawings no longer have an extra point at the start. |
TTSD-41518 | Drawings | Creating drawings could sometimes cause a Tekla Structures application error. This has now been fixed. |
TTSD-41609 | Drawings | Reinforcement in drawings: Occasionally drawings containing cut reinforcement bars showed circular ends although the bars were not tilted. This has now been fixed. |
TTSD-41649 | Drawings | Reference models in drawings: Reference model settings from GA drawing level were not properly propagated to view level. This has now been fixed. |
TTSD-41756 | Drawings | The Cover-up line command did not always hide the underlying object lines correctly. This has now been fixed. |
TTSD-40833 | Tekla Model Sharing | Previously, if Tekla Structures crashed or stopped working and you had to end the TeklaStructures process during write out in a shared model, you could not open the model again because of missing drawing files. This has now been fixed. |
TTSD-41077 | Tekla Model Sharing | Previously, imported sketched profiles in shared models could have parameters in the wrong order, which resulted in wrong geometry. This has now been fixed. |
TTSD-41149 | Tekla Model Sharing | Sketched profiles with variable sections are now updated correctly in shared models. |
TTSD-38837 | Reinforcement | Mirroring single leg rebar groups now works correctly for groups where the first or last bar is excluded. |
TTSD-39384 | Reinforcement | Previously, From plane offsets for tapered curved rebar groups were not always working correctly. This has now been fixed. |
TSAC-3351 | Modeling | Array of objects (29): Previously, when the copied objects included cuts and the cuts were not included in the component input objects, the cuts were left in the model after copying. This has now been fixed. |
TTSD-31138 | Modeling | Previously, diagnosing and repairing the model sometimes deleted valid parts of custom components when deleting incomplete parts. This has now been fixed. |
TTSD-33607 | Modeling | Welds are now listed in the Object locks dialog box. |
TTSD-34269 | Modeling | Previously, it was sometimes not possible to snap to the intersection point of a construction line and a construction circle because the snap zone was too strict. This has now been fixed. |
TTSD-37338 | Modeling | Bolt group lists now support more characters. |
TTSD-37917 | Modeling | Sometimes, after importing a sketched profile, and restarting Tekla Structures, other sketched profiles got corrupted and were showing incorrect properties in the profile catalog. This situation has now been fixed. |
TTSD-39520 | Modeling | View level filters (.vf ) files were not read from XS_PROJECT/XS_FIRM subfolders. This has now been fixed. |
TTSD-39553 | Modeling | When starting Tekla Structures, an error message is now shown if the user.config file is corrupted. |
TTSD-39962 | Modeling | Previously, negative imperial units were added together in the Move - Linear dialog box, for example. When you entered -3-5 , Tekla Structures interpreted it as -8" instead of 3'-5" . This has now been fixed. |
TTSD-40031 | Modeling | Previously, using the Undo and Redo commands when modifying user-defined attributes was not notified to applications that needed this information. This has now been fixed. |
TTSD-40381 | Modeling | Previously, the Zoom Selected command did not work in the model view if the drawing was open. This has now been fixed. |
TTSD-40397 | Modeling | Rebar sets: The hard-coded leg connection tolerance has been changed from 0.001 mm to 1 mm so that small inaccuracies in the leg faces do not prevent the legs from being connected to form one bar. |
TTSD-40517 | Modeling | In some cases, adding edges to items in the geometry editing mode sometimes failed. This has now been fixed. |
TTSD-41091 | Modeling | Previously, when creating a construction circle, it was not possible to snap to a part center line. This has now been fixed. |
TTSD-40297 | Core | Security fix for the parsing of the environment file profitab.inp |
TTSD-40684 | Core | When saving a model, Tekla Structures could in some cases crash when trying to open the message panel that is not in use anymore. This has now been fixed. |
TSAC-3234 | Tools and components | Previously, the pictures that you added in the custom component dialog editor were not shown in the custom component dialog box. This has now been fixed. |
TSAC-3371 | Tools and components | In Automatic Splicing Tool, a rebar group of two bars can now be correctly split and spliced and regrouped. |
TSAC-4738 | Tools and components | The Custom Component Dialog Editor tool now supports all the same value types as those available in the custom component properties. This means, for example, that you can now specify a variable value type as shape, which will give you access to the shape catalog in the component dialog box. |
TSAC-5020 | Tools and components | Previously, highlighting selected model points in Layout manager caused an error if Layout manager had not finished creating the tree structure of the group yet. This has now been fixed. |
TTSD-20740 | Tools and components | When importing custom components, if one or more custom components in a .uel file fails to import, the successfully imported components are now available. Previously, they were only available after reopening the model or importing a new .uel file. |
TTSD-39559 | Tools and components | When working with surface treatment inside custom components, each time a custom component was edited or copied, the surface treatment definition points were inserted into the new component twice. This has now been fixed. |
TTSD-41307 | Tools and components | Previously, adding a formula, such as "=P1 ", after a constant value in the custom component editor caused Tekla Structures to crash. This has now been fixed. |
TTSD-41529 | Tools and components | Previously, closing some dialog boxes could cause memory corruption or crashes. This has now been fixed. |
TTSD-41836 | Tools and components | In the Applications and components catalog, the search view was not updated when adding, removing or modifying items, for example macros. This has now been fixed. |
TTSD-8122 | Tools and components | The width of the Save as button has been increased in system component dialog boxes so that the Save as text is now shown correctly. |
TTSD-9404 | Tools and components | Previously, UDA equations could temporarily disappear in the Custom component browser. This has now been fixed. |
TTSD-38106 | Numbering | Reinforcing bar numbers are no longer shown as modified if you change the phase while the XS_ENABLE_PHASE_OPTION_IN_NUMBERING advanced option is set to FALSE . |
TTSD-40106 | User interface | You can now modify the rebar set rounding and step tapering properties in the custom component editor. |
TTSD-40501 | User interface | Previously, the hooks in a bent mesh did not keep the Custom hook setting when modifying the hooks in the property pane. This has now been fixed. |
TSAC-4764 | Import, export, interoperability (concrete) | Export Unitechnik (79): The Export project coordinates setting on the SLABDATE block data tab has been improved, and two new options Yes, project base point and Yes, current base point have been added. The option Yes, project base point uses project base point, and the option Yes, current base point uses the base point currently selected in the model. Furthermore, the option Yes has been renamed to Yes, model origin. |
TSAC-4815 | Import, export, interoperability (concrete) | Export Unitechnik export (79): For double walls, a different modeling method and the cast unit hierarchy caused that not all panels were correctly handled in the export. This has now been fixed. |
TSAC-4926 | Import, export, interoperability (concrete) | Export Unitechnik (79): You can now export line cuts, fittings and chamfers as MOUNPART block using the new setting Export cut edges on the Embeds tab. The geometry will be a simple line, and the MOUNPART s have fixed names. Line cuts and fittings are plotted along the cut edge. Chamfers are plotted at the inner line of the chamfered edge. |
TSAC-4966 | Import, export, interoperability (concrete) | Export EliPLAN file (68): Previously, weep holes were sometimes generated outside the element. This has now been fixed. |
TSAC-4967 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, no line attributes were recognized for edges that were diagonally cut completely. Now they can be scanned as chamfers or special formwork by managing the setting for chamfer maximum width. |
TSAC-4979 | Import, export, interoperability (concrete) | Export Unitechnik (79): Previously, in line attribute scanning, partial cuts at the edge of the element could occasionally cause other nearby edges to also have special formwork code. This has now been fixed. |
TSAC-4990 | Import, export, interoperability (concrete) | Export Unitechnik (79): Insulation exported as panel layer is now exported with correct layer type 02. |
TSAC-5092 | Import, export, interoperability (concrete) | Export Unitechnik (79): A new option Export shell gap width has been added on the SLABDATE block data tab to control or disable the export of the gap width value. The options are No - no gap is exported, Double wall only - the gap is exported only for double walls, and Layered panels - the gap is exported for all panels with multiple concrete layers, such as double walls and sandwich walls. The default option is Double walls only, as the value should only be used with double walls in most control systems. |