1
|
Length of the injection tube extension from the top of reinforcing bar.
|
180 mm
|
2
|
Reinforcing bar height in the column.
|
400 mm
|
3
4
|
Reinforcing bar top and bottom cover thickness.
The bottom cover thickness is used only if you do not define the top cover thickness.
|
0,5 * foundation plate thickness
|
5
|
Pile thickness.
The pile thickness value on the Parts tab overrides this value.
|
300 mm
|
6
|
Distance from the bottom of the foundation plate to the bottom of the pile.
|
5000 mm
|
7
|
Pile depth in the foundation plate.
|
50 mm
|
8
|
Foundation plate thickness.
|
800 mm
|
9
|
Distance between the column and the foundation plate.
|
0 mm
|
10
|
Vertical offset from the picked point.
|
0 mm
|
11
|
Reinforcing bar height.
|
800 mm 400 mm + 50% of height of concrete footing
|
12
|
Injection tube elevation 1.
|
500 mm
|
13
|
Injection tube elevations 2 and 3.
Vertical offset for the injection tubes if the tubes are pointing to the same direction.
Define the level to use on the Inj. Tube and rebar tab.
|
|