Use the Parts tab to control the profile properties of the foundation plate, foundation piles, stirrups and injection tubes in Concrete foundation (1030).
Concrete massive, Piles
Define the profile properties of the concrete foundation plate and the foundation piles.
If you leave the pile thickness value empty on the Parts tab, the pile thickness value defined on the Picture tab is used instead together with the Pile profile type prefix (e.g. D).
Option
|
Description
|
---|
t , b , h
|
Part thickness, width and height.
|
Pos_No
|
Prefix and a start number for the part position number.
|
Material
|
Material grade.
|
Name
|
Name that is shown in drawings and reports.
|
Class
|
Part class number.
|
Comment
|
Add a comment for the part.
|
Reinforcing bars
Option
|
Description
|
---|
Type of reinforcing bars
|
Select the profile type for the reinforcing bars.
Default : the same as Reinforcing bar
Poly-profile : profile catalog
Reinforcing bar : reinforcing bar catalog
|
Reinforcement bars
|
Size of the reinforcing bars.
|
Radius
|
Radius of the reinforcing bar hook.
|
Reinf. bars belong to
|
Define to which part the reinforcing bars belong.
Default : the same as Columns
Concrete massive : reinforcing bars belong to the concrete foundation plate.
Column : reinforcing bars belong to the column.
Loose part : reinforcing bars are not connected to any part.
Neighbor : reinforcing bars belong to the neighbor part. Use the name or class to find the part.
|
Injection tubes and curve
Option
|
Description
|
---|
Injection tubes
Curve
|
Size of the injection tubes.
Size of the injection hoses.
|
Article number
|
Article number for the injection hose and the injection tube.
The entered values are saved to the user-defined attribute of the part.
|
|
Define how the injection hoses are connected to the injection tubes.
Default : injection hoses are loose parts.
Part-add gain : injection hoses are added to the injection tubes.
Weld gain : injection hoses are welded to the injection tubes.
Cast unit column : injection hoses are added to the column.
Weld to column : injection hoses are welded to the column.
|
Option
|
Description
|
---|
Pile profile type prefix (e.g. D)
|
Default parametric profile prefix for the piles.
This value works only if you have set the pile thickness on the Picture tab.
You can override this value by setting the pile thickness on the Parts tab.
|
Reinf. bar profile type prefix (e.g.D)
|
Default parametric profile prefix for the reinforcing bar profiles.
|