Use the Diagnose & repair commands to check and to repair errors and inconsistencies in the structure of model objects and the library database ( xslib ). By diagnosing and repairing the model you can ensure, for example, that empty assemblies are removed and that unused points and attributes are deleted. Repairing the model also corrects invalid object relations and hierarchies. We recommend you to diagnose and to repair your model regularly to maintain the consistency and integrity of your model databases.

  1. On the File menu, click Diagnose & repair.
  2. Select the appropriate diagnose command.

    The errors and inconsistencies found in the model are listed in a report. Some of them are automatically corrected, some of them are warnings that you need to correct manually.

    If a profile, material grade, bolt element or assembly, or reinforcement seems to be missing from the corresponding cataloguser interface for displaying or modifying information in categorized lists

    For example, profile catalog and shape catalog are catalogs.

    , your Tekla Structures environment or a catalog filefile that defines catalog information used by Tekla Structures

    Catalog files have the extension .bin, .db, or .inp, for example.

    may not be the same as the model's original one.

    The following table lists the most common errors and inconsistencies found when diagnosing the model.

    Diagnosis result

    Description

    Action needed

    Empty assembly

    The assembly does not contain any objects.

    1. On the File menu, click Diagnose & repair.
    2. Under Model , click Repair model to delete the assembly.

    Missing assembly

    A part is not included in any assembly.

    1. On the File menu, click Diagnose & repair.
    2. Under Model , click Repair model to create an assembly and to move the part to it.

    Illegal profile

    An unknown profile has been found.

    1. Ensure that you are using the correct Tekla Structures environment.
    2. Use the model's original profdb.bin and profitab.inp files and save them in the model folder.
    3. Reopen the model.

    Illegal material

    An unknown material grade has been found.

    1. Ensure that you are using the correct Tekla Structures environment.
    2. Use the model's original matdb.bin file and save it in the model folder.
    3. Reopen the model.

    Illegal bolt

    An unknown bolt element or bolt assembly has been found.

    1. Ensure that you are using the correct Tekla Structures environment.
    2. Use the model's original screwdb.db and assdb.db files and save them in the model folder.
    3. Reopen the model.

    Illegal reinforcing bar size or grade

    Illegal reinforcement mesh

    Reinforcement with invalid properties has been found.

    1. Ensure that you are using the correct Tekla Structures environment.
    2. Use the model's original rebar_database.inp and mesh_database.inp files and save them in the model folder.
    3. Reopen the model.

    Invalid rebar geometry

    Reinforcement with undefined geometry has been found.

    See Check the validity of reinforcement geometry.

    If the model does not contain any errors or inconsistencies, a message is displayed on the status bar.

Quick feedback

The feedback you give here is not visible to other users. We use your comments to improve our content.
We use this to prevent automated spam submissions.
Content rating: 
No votes yet

Comments

by Paulius Vasiliauskas

what about:
"A SERIOUS INCONSISTENCY HAS BEEN DETECTED!"
"Please contact Tekla Structures support for instructions"
"Maximum id in database (62986238) > current id (1860416)"

by Anu from Tekla User Assistance

Hi,

The inconsistency is typically fixed by using the 'Repair model' command. (You may need to run the command several times.)
If this fails, in some situations you can run a report that lists all id's. Then you can check which row in the report contains the maximum id. Select that report row to find the part in the model and then delete the part.
If this does not help, please contact your local support: https://teklastructures.support.tekla.com/browse-local-support

by Paulius Vasiliauskas

This error is in library database. how can i run a report through it ?

by Anu from Tekla User Assistance

Hi,

If the error is in the library database, it's definitely best that you contact your local support. They could check your model.